Artificial urinary sphincter in Madrid: Urinary control when all else has failed
The artificial urinary sphincter (AUS) is the gold standard treatment for stress urinary incontinence that has not responded to pelvic floor rehabilitation or other conservative treatments. The AMS 800 device mimics the function of the natural sphincter and restores permanent urinary control to the patient, with long-term continence rates exceeding 90%. At our center, Dr. Moncada and Dr. Moscatiello have extensive experience in the implantation, follow-up, and replacement of this device in both men and women.
Who is a candidate for an artificial urinary sphincter?
The artificial urinary sphincter is the gold standard treatment for stress incontinence that has not improved with conservative treatments such as pelvic floor rehabilitation, medication, or periurethral injections. The most common candidates are men with post-radical prostatectomy incontinence and women with refractory stress incontinence following previous unsuccessful surgeries. It is also indicated for patients with neurogenic incontinence when the sphincter mechanism is irreversibly damaged.
How the AMS 800 Artificial Urinary Sphincter Works
The AMS 800 is the most widely implanted device in the world for the treatment of urinary incontinence. Its mechanism mimics the function of the natural urethral sphincter with a precision and reliability that no other treatment can match.
Components of the AMS 800 device
The system consists of three interconnected components: the occlusive sleeve, the pressure reservoir, and the control pump. The entire system operates using saline solution and remains completely hidden under the skin.
How Patients Control Urination with an Artificial Sphincter
At rest, the cuff compresses the urethra and automatically maintains continence, without the patient having to do anything. When the patient wants to urinate, he presses the pump located in the scrotum or on the labia majora, which transfers fluid from the cuff to the reservoir, opens the urethra, and allows urination. After 3–5 minutes, the fluid automatically returns to the cuff, restoring continence. The mechanism is easy to learn, and within a few weeks it becomes a completely natural reflex.
Robotic-assisted artificial urinary sphincter for women
In women, the implantation of an artificial urinary sphincter is technically more complex than in men. At our center, we use the robotic approach for the female sphincter, a technique that Dr. Moscatiello has presented at national and international conferences and that allows for more precise placement of the sleeve around the bladder neck, with a lower risk of erosion and better long-term results.
Why the AMS 800 Is the Gold Standard for Refractory Urinary Incontinence
With over 40 years of clinical history and more than 200,000 implants performed worldwide, the AMS 800 remains the device with the strongest scientific evidence for the treatment of urinary incontinence when other options have failed. It provides continuous continence without any effort on the patient’s part, a significantly higher quality of life than that offered by absorbent products or intermittent catheters, and long-lasting results with a mechanical survival rate of over 80% at ten years. There is no other treatment for incontinence with comparable long-term results.
Results of artificial urinary sphincter surgery at our center
Our team’s results show continence rates exceeding 90% five years after implantation. The reoperation rate due to mechanical complications or erosion is less than 10% during that period. In cases of device malfunction or failure, replacement of the artificial sphincter is technically possible, with results equivalent to those of the initial surgery. Both Dr. Moncada and Dr. Moscatiello have published experience in revision surgeries and artificial sphincter replacement.
What the artificial sphincter surgery and device activation involve
The implantation of an artificial urinary sphincter requires general or spinal anesthesia and takes between 60 and 90 minutes. We’ll walk you through the entire process so you know what to expect before and after surgery.
The Surgical Procedure and Hospital Stay
Through a perineoscrotal incision in men or an abdominal/laparoscopic incision in women, the surgeon places the sleeve around the urethra, the reservoir in Retzius’s space, and the pump in the scrotum or the labia majora. The device is implanted in a deactivated state to allow for proper healing. The hospital stay is 2–3 days, and a urinary catheter is worn for the first few days.
Sphincter Activation and Continence Recovery
The device remains deactivated for the first 4–6 weeks to allow the urethra to heal properly around the sleeve. At the follow-up appointment, the urologist activates the system and teaches the patient how to operate the pump. Continence is gradually restored over the following weeks. Most patients achieve full continence between 6 and 12 weeks after activation.
▶ Explanatory video on the AMS 800 artificial urinary sphincter—how it works and what to expect after surgery
Are you still using pads to manage urinary incontinence?
An artificial sphincter can permanently restore your continence. Consult with our team.
The team that implants the artificial urinary sphincter in Madrid
Dr. Ignacio Moncada and Dr. Pietro Moscatiello are the leading experts on our team in urinary implantology. Dr. Moncada has decades of experience in urological prosthetics and has published on revision techniques for artificial sphincters. Dr. Moscatiello is a specialist in functional urology and pelvic floor medicine, with specific expertise in robotic implantation of the female sphincter and sacral neuromodulation. They have presented their findings at major national conferences on functional urology, including the meetings of the AEU’s Functional, Female, and Urodynamic Urology Group.
Patients Who Regained Continence with an Artificial Sphincter
Real reviews from patients who have regained urinary control with an artificial sphincter implant at our center. Taken from Google Business Profile and verified health platforms.
Publicado en Google![]()
Maiko ArgudoTrustindex verifica que la fuente original de la reseña sea Google.
Muy buenoPublicado en Google![]()
Manolo BTrustindex verifica que la fuente original de la reseña sea Google.
Contentisimo con la atención (siempre disponible) y la profesionalidad del Dr. Moncada y su equipo. Todo lo hicieron fácil y los resultados inmejorables. 100% recomendable.Publicado en Google![]()
Loli GTrustindex verifica que la fuente original de la reseña sea Google.
El doctor Ignacio Moncada me parece uno de los mejores o Pero a mi marido con el robol davinchi y fue un esitoooo .como el nos dijo le aconsejó a todo el k este pasando por está situación de cáncer de próstata que Acuda a este urólogo. Trato especial y en todo momento nos dio paz y seguridad.Publicado en Google![]()
Alejandro Suárez GonzálezTrustindex verifica que la fuente original de la reseña sea Google.
No tuve que esperar mucho a que me atendiese y el Dr. Moncada estuvo muy atento en todo momento. Recomendable.
Frequently Asked Questions About the AMS 800 Artificial Urinary Sphincter
Is the artificial sphincter visible from the outside?
No. The three components of the device are completely implanted under the skin and are not visible from the outside. The pump is located in the scrotum or the labia majora and is practically imperceptible to the touch when at rest. The patient can lead a completely normal life without anyone knowing he has the device.
Can I play sports with an implanted artificial sphincter?
Yes. Once the recovery period is over, the patient can resume any physical activity, including high-impact sports. The device is designed to withstand everyday physical exertion without compromising its function or continence.
How long does an artificial urinary sphincter last?
The AMS 800 device has a mechanical survival rate of over 80% at ten years. Over time, the mechanism may wear out or a complication may arise that requires replacement. Our team provides indefinite follow-up care for the patient, and if at any time it becomes necessary to replace the device, reoperation is technically possible with equivalent results.
What is the difference between an artificial sphincter and incontinence mesh?
Suburethral mesh implants (TOT or TVT type) are indicated for stress incontinence in women with an intact sphincter mechanism. The artificial sphincter is reserved for cases in which the sphincter mechanism is irreversibly damaged. These are complementary treatments, not alternatives.
Other Treatments for Urinary Incontinence at Our Center
If you’re looking for a less invasive alternative to an artificial sphincter, these are the treatments we also offer.
Botox
For urge incontinence and overactive bladder that do not respond to oral medication. A minimally invasive, outpatient alternative.
Surgery for Female Incontinence and Prolapse
Suburethral mesh for mild-to-moderate stress incontinence in women with intact sphincter function.
Blog posts about the artificial sphincter and incontinence
Our team publishes content on advances in artificial urinary sphincter implantation, long-term outcomes, and post-surgery care. Written by the specialists who perform the procedure.
New Frontiers in Uro-Oncology: Sanitas Continuing Education Program for Healthcare Professionals
As on previous occasions, Dr. Moncada participated in the “New Frontiers in Uro-Oncology” sessions, which are part of Sanitas’s “continuing education program for
2nd Gregorio Marañón Conference: The Impact of New Technologies on Urology
Dr. Moncada participated in the 2nd Gregorio Marañón Conference: Impact of New Technologies in Urology on March 27 in Madrid, where he gave a presentation
You’ve been living with incontinence for some time, and a permanent solution is within your reach
The AMS 800 artificial urinary sphincter has restored continence and quality of life to thousands of patients worldwide. If rehabilitation and other treatments haven’t worked, this may be your next step. Call us or schedule an appointment with our team.